330kV 3-Phase 2-Winding Power Transformer

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Beijing
Validity to: Long-term effective
Last update: 2022-09-16 08:20
Browse the number: 89
inquiry
Company Profile
 
 
Product details

Part Ⅰ: 330kV Power Transformer Overview

330kV series oil-immersed power transformers adopt advanced calculation software to accurately calculate the ampere-turn balance, various stresses, temperature rise, and insulation distance; accurately analyze the electromagnetic field, magnetic flux leakage, and wave processes; use plane and three-dimensional dynamic model simulation design to ensure reliable product performance, The structure is reasonable.


330kV power transformers are mainly made of iron core and windings, which are placed in the oil tank that filled with insulating oil. It is mainly used for power plant, power transmission and distribution station as the equipment of power transmission.


330kV 3-phase 2-winding Power Transformer

Product Attributes

Model No.


Application

Power

Coil

Core-type Transformer

Frequency

50/60Hz

Phase

Three

Cooling Method

Oil-immersed Type Transformer

Capacity range:

150000kVA-400000kVA

Operating Ambient Temperature

+40 °C--30 °C

Operating Altitude

≤1000m

Operating Max Wind Speed

≤35m/s

Earthquake acceleration

horizontal acceleration ≤0.3g

vertica I acceleration ≤0.15g

Standard

IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc.

Supply Ability & Additional Information

Packaging

Seaworthy Packing

Transportation

Ocean

Supply Ability

High

HS Code

85042100

Payment Type

L/C,T/T

Delivery Time

60 Days

Place of Origin

China

Port

China Sea Port

Incoterm

FOB, CFR, CIF

Packaging & Delivery

Selling Units:

Set/Sets

Package Type:

Seaworthy Packing


Part Ⅱ: Product Features

1. High Reliability:

Short circuit strength: through the analysis of leakage magnetic field of transformer, the electromagnetic force can be well controlled in the structure design, and together with equipment and suitable materials, the requirement of short circuit strength can be sufficiently satisfied. Our design method has been testified through short circuit test on products at different voltage levels, which also testifies that our products have enough strength against short circuit.



2. Low power loss and low operation cost

The transformer has relatively low losses through the optimized design, the detailed analysis of leakage magnetic field and the losses distribution. The maintenance cost has been lowered through the Customer-oriented design.



3. Customer-oriented Design

Based on the 3D design method to simulate feeders, operation filed and terminal box arrangement are in full consideration of operating conveniences, which meets the requirements on cost lowering and customization, as well.


Part Ⅲ: Structural Feature

1. Iron Core

Iron core with fixed clamps optimizes the design so as to ensure mechanical strength and to reduce leakage losses.



2. Winding

① HV winding adopts entanglement or inner screened continuous type with phase insulation structure to ensure insulating strength.

② MV/LV windings adopt high strength or adhibit-transpostion conductor, reinforced cooling to reduce the temperature rise and enhance capability of short circuit withstand.


3. Active-parts Assembly

① Cold pressing ensures cleanness of the body active parts and the reliability of leads.

② Adoption of whole assembled phase insulation so as to reduce the assembly time and effectively guarantee the dimension and shape of the insulation structure.

③ HV lead adopts specially molded insulation parts for protection which effectively guarantees its insulating strength and reduces partial discharge.



4. Oil Tank

Adopting of welding automatic submerged arc-welding and ultrasonic of fluorescence leakage test to guarantee leakage -free The surface coating is strictly controlled.



5. Assembly and Routine Test

After assembly, strict pre-delivery test according to standard, with exquisite testing technique and equipments to provide high quality and reliable product.


Part Ⅳ: Product Main Parameter

330kV Two-winding Oil-immersed Transformer
Rated Capacity (kVA) Rated Voltage and Tapping Range Vector Group Impedance Voltage % No Load Current

%
No Load Losses

kW
On Load Losses

kW
HV LV
150000 363±2×2.5% 10.5~20 YNd11 14~15 0.3 90 400
400000 0.15 185 820


330kV Three-winding Oil-immersed Transformer
Rated Capacity (kVA) Rated Voltage and Tapping Range Vector Group Setp-up set Impedance Voltage (%)
HV MV LV No Load Current

%
No Load Losses

kW
On Load Losses

kW
HV-MV HV-LV MV-LV
150000 330±8×1.25% 110~121 10.5~35 YNyn0d11 0.3 95 440 14~15 24~26 7~9
240000 0.25 135 625
360000 0.15 185 850
150000 YNa0d11 0.3 50 335 11~12 34~36 22~24
240000 0.25 70 480
360000 0.15 95 645


Part Ⅳ: Structural Diagram


Part Ⅴ: Quality Warranty


Part Ⅵ: Application


Part Ⅶ: Packaging and Transportation


Before packing the transformer, make a packing plan, and carry out packing according to the design scheme and plan when packing. The packing list corresponds to the materials in the box one to one. Pack the box in two copies, one in the packing box and the other nailed outside the packing box. Important parts and spare parts are packed in wooden boxes, and the box numbers are set in order.

The transformer is transported in bare installation, and the fuel tank is emptied before transport. It is tied to a transport vehicle by a wire rope, and the transport speed does not exceed 15km/h.

The terminal is guaranteed to have large-scale transformer lifting equipment, and the lashing is firm after loading to ensure safe and reliable transportation.


Part Ⅷ: Factory Tour


Part Ⅸ: Service Guarantee

1. To provide all technical information and drawings as per contract promptly. QRE is oblidged to invite client, if neccessory, technical design review.

2. To carry out spot technical service as per client’s schedule, offer guideness for installation and commis-sioning according to technical information and drawings.

3. For relevant auxiliary equipment procured by customers, QRE will provide related technical information to meet requirement of equipment interface.

4. To execute stipulations in MOU or agreemaent signed by seller and buyer strictly.

5. To train staff from client for equipment installation, commissioning, application, maintenance as stipulated in the contract.

6. To reinforce pre-sales, mid-sales, after-sales service, to carry out "24-hour service", "service in advance", "overall process service", "lifelong service" in our manufacturing, installation, commissioining and main-tance.

7. To meet spare parts’ requirement by customers at any time.


Part Ⅹ: Contact Us

Looking for ideal 330kV 3-phase 2-winding Power Transformer Manufacturer & supplier ? We have a wide selection at goods prices to help you get creative. All the330kV 3-phase 2-winding Power Transformer are quality guaranteed. If you have any question, please feel free to contact us.


http://www.hydgetpower.com/

Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]